Ultra High Performance High PerformanceLiquid Chromatography System (Customized)
Brand BIOBASE
Product origin CHINA
Delivery time Within 7 days
Supply capacity Factory Direct Supply
Model BK-1800UHPLC
Introduction:
EClassical 3100 System is perfected from classical HPLC systems manufactured by our company, the high quality has widely recognized by customer. It is suitable for users who are looking for the versatility and robustness. The excellent features ensure the reliability results and improve working efficiency.
Download
BK-1800UHPLC
Ultra High Performance /High Performance Liquid Chromatography System
Details defne quality from visible to invisible
Designed by an Internationally awarded Companies
With full functional confquration to meet various application needs of industries
The infusion unit is driven by a linear motor with leading technology, which signifcantly improves theaccuracy and precision
Easily deal with complex samples by the strong separation performance of two-dimensional separationssystem
Professional workstation software, are complies with GMP, FDA 21 CFR, 30 and other regulatory certifcationrequirements
Binary Pump
Confguration: Ultra-high-performance binary Infusion System (120MPa), Ultra-high-performance binary InfusionSystem (62MPa, 90MPa)
Ultra-high-performance binary infusion system can be equipped with two types of infusion deviceType l: Reciprocating infusion pumps, High flow accuracy, Low pressure pulsationType ll: Linear motor digital-driven pump, Infusion stability, Mixing accuracySolvent type selection according to the mobile phase, and automatic adjustment of liquid compression compensation
Automatic post-column rinsing, the cleaning flow rate can be controlled according to actual needs
EX1800 UHP/UBP
Infusion System: Linear motor digital-driven pump
Flow range: 0.001-5mL/min,n0.001mL/min increments
Maximum operating pressure: 120MPa(corresponding 17000psi)
Flow precision: ≤0.06%RSD
Flow accuracy: ≤±0.3%
compression compensation: Automatic,continuous, selectable solvent type
Post-column cleaning: Automatic post-column cleaning function, which can control the cleaning fow rate
Gradient setting range: 0-100%
Extended application: Record number of times the plunger rod seal is used
EX1800 UHP/UBP
Infusion System: Type l Reciprocating infusion pumps
Type ll Linear motor digital-driven pump
Flow range: 62MPa 0.001-10 mL/min,n0.001mL/min increments
90MPa0.001-5mL/min,n0.001mL/min increments
Maximum operating pressure: 62MPa(corresponding 9000psi),90MPa(corresponding 13000psi)
Flow precision: ≤0.06%RSD
Flow accuracy: ≤±0.3%
Compression compensation: Automatic, continuous, selectable solvent type
Post-column cleaning: Automatic post-column cleaning function, which can control the cleaning flow rate
Gradient setting range: 0-100%
Extended application: Record the number of times the plunger rod seal is used
Quaternary Pump
1.Maximum pressure ofthe quaternary pump can reach to 70MPa
2.Solvent type selection according to the mobile phase, and automatic adjust-
ment of liquid compression compensation
3.Automatic post-column rinsing, the cleaning flow rate controlled according to actual needs.
Infusion System: Linear motor digital-driven pump
Flow range: 0.001-10mL/min,n0.001mL/min increments
Maximum operating pressure:70MPa(corresponding 10150psi)
Flow precision:≤0.06%RSD
Flow accuracy:≤±0.3%
Compression compensation:Automatic, continuous, selectable solvent type
Post-column cleaning:Automatic post-column cleaning function, which can control the cleaning fow rate
Gradient setting range:0-100%
Online degassing:Degassing channel Systec AF®
Extended application:Record the number of times the plunger rod seal is used
UV Detector
1. The newly designed circuit system and light path structure greatly improve the sensitivity of the detector
2. Optional: UV detector and ultra-effcient UV detector
3. Usage of 2000 hours of high-performance deuterium lampFront-loader flow cell and light path structure design,easy to maintain and replace
4. Continuously perform spectral scanning or absorbance measurement under2 wavelengths(EX1800 UV D)
EX1800 SUVHigh-efficiency Ultraviolet Light Detector
Flow cell:volume 1.0uL; adopts cone structure /With optional temperature control module
Light source:Deuterium lamp
Wavelength range: 190-700nm
Spectral bandwidth: 4nm
Wavelength accuracy: ±1nm
Wavelength precision: <0.1nm
Noise:≤0.25*10sAU (static)/≤4*10³AU (dynamic, under specifed test conditions)
Drift:≤0.4*10*AU/h (static)/≤5*10^AU/h (dynamic, under specifed test conditions)
Sampling frequency: Up to 100HZ
EX1800 UV/UV D Ultraviolet Light [UV] Detector EX1800 UV VIS
Flow cell:Volume 10.0uL; adopts cone structure /With optional temperature control module
Light source:Deuterium lamp Light source:Deuterium lamp+ tungsten lamp
Wavelength range:190-700nm Wavelength range: 190-900nm
Spectral bandwidth:8nm
Wavelength accuracy:±1nm
Wavelength precision:<0.1nm
Noise:≤0.25*10'AU (static)/≤4*10'AU (dynamic, under specifed test conditions)
Drift:≤0.4*10-*AU/h (static)/≤5*10*AU/h (dynamic, under specifed test conditions)
Sampling frequency:up to 100HZ
PDA Detector
1.Spectral scanning or absorbance measurement can beperformed continuously at a frequency of 100 Hz under 8 wavelengths
2.The wavelength range is 200nm to 800nm, adjusted in 1nmincrements
3.Both deuterium lamp and tungsten lamp use built-in counter tocalculate working time
4.Support 3D spectrogram
EX1800 POA
Number of diode arrays: 1024
Light source: deuteriumlamp+tungsten lamp
Wavelength range: 200-800nm
Wavelength accuracy:±1nm
Wavelength precision:+0.5nm
Noise: +5*10-6AU,under specifed conditions
Drift: 1*10-4AU/h, under specifed conditions
Sampling frequency: up to 100HZ
Spectral bandwidth:10nm
Flow cell path length:5mm(10mm is optional) Up to 8 channels of digital signal output
FL Detector
1.Use high-performance flash xenon light source
2.With the newly designed optical system,achieved highsensitivity and fast analysis capabilities
EX1800 FL D
Light source: Xenon lamp
Wavelength range: 190-890nm
Spectral bandwidth: 6nm,8nm,18nm,40nm
Wavelength accuracy: ±2nm
Wavelength reproducibility:±0.2nm
Flow cell path length: Standard flow cell 12uL
ELS Detector
1.Super long life laser light source
2.Special designed constant temperature device to ensure the Stability ofthe evaporation temperature
3.Built-in gas mass flow control system, not affected by pressure changes Special designed temperature-controlled atomizer to prevent instability
4.caused by the atomization process
EX1800 ELSD
Light source: 650nm laser,maximum output 30mW
Atomizer(nozzle)temperature control range:3°C-80°C above room temperature, with 1°C step
Drift tube temperature control range:3°C-130°C above room temperature, with 1°C step
Drift tube temperature stability:+0.03°C
Gas flow setting range:0.0-5.0 L/min
Noise:≤0.015mV
Drift:≤0.025mV/30min
RI Detector
1. The dual temperature control system shortens the time from turning on the power switch to the stabili.Zation of the instrument, and ensures good baseline stability
2. Have a leak sensor
EX1800 RI
Refractive index range: 1.00-1.75RIU
Detection range:0.25-512µRIU
Noise:≤2.5nRlU (pure water response time: 1.5 seconds)
Temperature control:Off, 30°C-50°℃,with 1'c step
Flow cell volume:8µL
Column Drganizer
1.Column Compartment Thermostatting and Preheating for Temperature to reduce temperature changes so that the chromatographic peak shape can be more symmetrical
2.Large-capacity structure, convenient to place 4 x 30cm chromatographiccolumns or 8x5cm,10cm ultra-effcient columns
3.With multi-channel switching valve, can achieve chromatographic column switching or multi-dimensional liquid phase applications
EX1800 CD
Temperature control range:5°C-80°C above room temperature
Ceramic heating module±0.1°C
Temperature stability:Temperature accuracy:±0.5°C
Up to two pre-post preheaters
Column capacity: up to 4x 30cm columns (ultra-efhcient columns 8x5cm,10cm), Optional: column switching valve
Temperature control method: microcomputer controlled active air circulation
EX1800 CD ll
15°C-80'C at room temperature (minimum setting temperature 4°C)Semiconductor refrigeration module
Solvent Drganizer
1.Equipped with online vacuum deaerator
2.Basically provides 4 degassing channels to achieve 4 mobile phase degassing
3.Two-way mobile phase switching valve can be confqured, to expandthe original two-way mobile phase input of the binary high-pressure gradient to two sets of two (4 in total)mobile phase input
4.Degassing channel Systec AFe -degassing channel volume is 380μL/channel
Autosampler
1.Self-protection function, misoperation preventing,effectively reduce serious damage to equipmentcaused by misoperation
2.The injection range is 0.1~120μL,ensuring high-pre-cision injection of both large and small-volumesamples
3.Various optimization measures are adopted toreduce cross-contamination of samplesUp to 330(1mL) can be placed;
4.Provides two options: standard and ultra-effcient
5.Quadruple protection device,with optional: refrigerationfunction
6.Programmable sampling
program, sample pretreatment,automatic dilution, automaticpre-column derivatization andother functions
EX1800 UAS U/AS
Type l: The number of samples: With total two side, eachside can choose one type oftray. The system automaticallyrecognizes the tray specifcations.
Maximum number: 1mLx192; 2mlLx108 (standardconfguration); 4mLx70; 10mLx30;
Type ll: The number of samples: With total two side, eachside can choose one type oftray.The system automaticallyrecognizes the tray specifcations.Maximum number:1mLx330; 2mlLx192 (standardconfguration); 4mLx108; 10mLx48;
Cross contamination: s0.005% (specifed cleaningprocedure)
Injection volume: 0.1-120ul (determined based on thesample loop)
Injection accuracy: Full sample loop, RSD6s0.25%; partialquantitative loop, RSD6s0.596
Automatic protection function: Alarm for lack of bottle.thimble alarm, pipeline blockage alarm, leakage alarmRefrigeration function: Optional refrigeration module