Gas Chromatograph BK-GC906
Brand BIOBASE
Product origin CHINA
Delivery time Within 7 days
Supply capacity Factory Direct Supply
Model BK-GC906
Introduction:
This instrument perfectly blends cutting-edge technology with user-friendly design, marking a significant advancement in the field of analytical instruments. Equipped with an industry-leading technology platform and a self-developed advanced data processing system, it not only achieves superior performance but also significantly enhances ease of use, ushering in a new era of intelligent analysis for users and contributing technological power to the development and innovation of related industries.
Download
Features:
1. Supports up to 18 channels of high-precision electronic pressure/flow control (EPC).
2. Featuring a 10-inch high-definition capacitive touchscreen, it can display spectra, all temperature zones, carrier gas flow rates, detector functions, etc. in real time.
3. Instrument methods can be edited on-screen, and firmware versions can be upgraded via USB interface.
4. One-click instrument reset is supported.
5. Intelligent maintenance tracking and reminders are provided, indicating the replacement time for injection pads, liners, etc.
6. The pre- and post-chromatographic channels can be controlled and operated synchronously or asynchronously.
7. It has undergone rigorous functional safety ECM certification, comprehensively enhancing its anti-interference capabilities.
Technical Parameters:
Model | BK-GC906 | |
Oven | Temperature Range | RT+2~450℃ |
Temperature Control Accuracy | 0.01℃ | |
Temperature Program | ≥99 levels, 100 platform (expandable) | |
Maximum Temperature Heating Rate | 250ºC/min | |
Temperature Control System | An 8-channel independent temperature control system with automatic temperature protection function | |
Selectable Detector Types | Flame Ionization Detector (FID) | Operating temperature: 450℃ |
Detection limit ≤1.1pg C/s (n-hexadecane) | ||
Baseline drift (30 min) ≤ 2*10⁻¹³ A | ||
Baseline noise ≤2*10⁻14A | ||
Dynamic linear range ≥10⁷ | ||
Automatic ignition function | ||
Thermal Conductivity Detector (TCD) | Sensitivity≥10,000 mV·mL/mg | |
Baseline drift (30min): ≤0.2mV | ||
Baseline noise: ≤0.05mV | ||
Dynamic linear range: ≥10⁵ | ||
Safety protection: Gas bridging current protection function | ||
Flame Photometric Detector (FPD) | Maximum operating temperature: 450℃ | |
Limits of detection: P ≤ 80 fg/s (methyl parathion), S ≤ 8 pg/s (methyl parathion) | ||
Dynamic linear range: P≥10³; S≥10² | ||
Equipped with automatic ignition function | ||
Electron Capture Detector (ECD) | Radioactive source: 63Ni | |
Maximum operating temperature: 400℃ | ||
Limit of detection: ≤1.0*10-14 g/mL (γ-666) | ||
Dynamic linear range: ≥10⁴ | ||
Nitrogen-phosphorus Detector (NPD) | Maximum operating temperature: 400℃ | |
Limit of detection: N: ≤1*10⁻¹² g(N)/s (azobenzene); P: ≤5*10⁻¹³ g(P)/s (malathion) | ||
Dynamic linear range: N≥10³, P≥10³ | ||
Selectable Sample Injection Method | It can be used with standard and inert flow path split/splitless capillary injection, septum purge packed column injection, cold column injection, programmable temperature vaporization injection ports, valve injection systems, headspace injection systems, thermal desorption injection systems, etc. | |
Standard Accessories | FID detector, chromatography workstation software, capillary sampler | |
Optional Accessories | Sample injection system, TCD, ECD, FPD and NPD detector, chromatographic column, nickel catalytic converter | |
Power Supply | AC220V, 50/60Hz | |
610*530*500mm | ||
Net Weight | 50kg | |
Packing Size(W*D*H) | 800*640*750mm | |
Gross Weight | 63kg | |
Remark: 2 different types of detectors can be installed simultaneously.








