Automated NGS Library Preparation Workstation (Customized)
Brand BIOBASE
Product origin CHINA
Delivery time Within 7 days
Supply capacity Factory Direct Supply
Model Auto-NGS 200
Introduction:
Auto-NGS 200 is a one-stop library preparation workstation for library preparation, quantitation, multiplex targeting, and hybridization capture. With a built-in 24-well fluorometer and PCR amplification block, it truly achieves convenient operation of sample-to-library, without manual intervention throughout the whole process. The 27-plate design with gripper and plate stacking allows for relatively simple library preparation for 96 samples, as well as fully automated library preparation and hybridization capture for a simplified type of 48 samples.
Download
Features:
1.24-channel pipettor (1~200 µL).
2.24-well fluorometer for automatic concentration detection.
3.Built-in PCR for amplification and hybridization.
4.Thermo shaker incubator to enhance the mixing effect.
5.Maximum processing capacity: 96 samples.
6.Plate layout: 27 plate positions.
7.Two robot arms, multiple blocks simultaneous operation.
Parameters:
Item | Specification |
Model | Auto-NGS 200 |
Throughput | 1~96 |
Tiles number | 25 standard tiles + (TIP off box + waste liquid area) |
Pipettor | Specification: 200 µL; 24-channel (can be used as a single channel)Pipetting range: 50 µL tip: 1-200 µL; 200 µL tip: 2-200 µLMinimum detection volume: 20 µL |
Pipetting precision | 1 µL: ≤8 %; 2 µL: ≤5 %; 5 µL: ≤4 %; 20 µL: ≤1 %; 100 µL: ≤1 %; 200 µL: ≤1 % |
Pipetting accuracy | 1 µL: ±10 %; 2 µL: ±8 %; 5 µL: ±4 %; 20 µL: ±2 %; 100 µL: ±1 %; 200 µL: ±1 % |
Temperature control block | Including 2 temperature control blocksTemperature control range: 4~105 °CTemperature control accuracy: ≤1 °CTemperature control uniformity: ≤1 °C @55 °C |
Gene amplification block | Temperature control range: thermo lid: +30 °C~+120 °C; block: +4 °C~+99 °CUniformity: ≤0.7 °CAccuracy: ≤±0.3 °C |
Fluorescence detection range | 0.4 ng~100 ng |
Automatic clamping and heating mixing block | Yes |
Magnetic plate | 96-well annular magnetic plate |
Gripper | Including one |
Stacking plate lifting block | Including one |
UV sterilization | Equipped with UV sterilization lamp, HEPA device |
Instrument port | USB port |
Information management | External scanner for entering sample/reagent informationExpandable LIS system connectionExpandable cloud database connection |
Ambient condition | Temperature requirement: 20±5 °CRelative humidity: ≤80% |
Power input | 100~240 V, 50 / 60 Hz, rated power 1200 W |